The following chart
and graphs show the speeds and air
consumption for the various capacities of Frame 2 Herculink
at different loads. This chart is useful in calculating
cycle times when the loads are known. Choose a load on the
left hand column, read across to find the up and down speeds.
The graphs allow you to pinpoint speed and air flow for
a selected capacity. All performance figures are based on
a 980 psig (6.2 bar) at the inlet with the motors operating
(dynamic vs. static). Loads are in metric tons (2200lbs/ton).
HERCULINK
FRAME 2 PERFORMANCE
Line Pressure (motor running) at Motor inlet:
90 psig (6.2 bar)
Hoist
Capacities
Air
flow for all sizes
12-1/2
ton
25
ton
Hoist
Speed
Hoist
Speed
Load
Ft/min
Load
Ft/min
Up
Scfm
Ton
Up
Down
Ton
Up
Down
Scfm
up
down
0
19
7
0
9.5
3.5
275
140
.25
19
8
.5
9.5
4
260
140
1.17
18
8.5
2.3
9
4.25
240
140
2.1
17
10
4.2
8.5
5
230
140
3.01
16
10.5
6.0
8
5.25
230
150
5.09
14
11
10.2
7
5.5
220
160
7.21
12
12
14.4
6
6
210
160
11.04
8
14
22.1
4
7
180
150
12.6
7
16
25.2
3.5
8
150
150
15.68
Stall
31.4
Stall
HERCULINK
FRAME 2 PERFORMANCE
Line Pressure (motor running) at Motor inlet:
90 psig (6.2 bar)
Get the scoop from IR's experts! IR's
Uplink news letters provide answers to frequently asked technical
questions, including specs and diagrams where appropriate.