Ingersoll Rand Corporation

On Sale Now
News & Announcements
Products
Technical Publication
Technical Support
Warranty
Literature Request


Product: Herculink Air

Models: HA2, Frame 2

Subject: Performance Chart & Graphs

By: Manjit Bains, Hoist Engineering

No. UL-019

Date: 06/30/98

The following chart and graphs show the speeds and air consumption for the various capacities of Frame 2 Herculink at different loads. This chart is useful in calculating cycle times when the loads are known. Choose a load on the left hand column, read across to find the up and down speeds. The graphs allow you to pinpoint speed and air flow for a selected capacity. All performance figures are based on a 980 psig (6.2 bar) at the inlet with the motors operating (dynamic vs. static). Loads are in metric tons (2200lbs/ton).

 

HERCULINK FRAME 2 PERFORMANCE

Line Pressure (motor running) at Motor inlet: 90 psig (6.2 bar)

Hoist Capacities

Air flow for all sizes

12-1/2 ton

25 ton

  

Hoist Speed

 

Hoist Speed

Load

Ft/min

Load

Ft/min

Up

Scfm

Ton

Up

Down

Ton

Up

Down

Scfm up

down

0

19

7

0

9.5

3.5

275

140

.25

19

8

.5

9.5

4

260

140

1.17

18

8.5

2.3

9

4.25

240

140

2.1

17

10

4.2

8.5

5

230

140

3.01

16

10.5

6.0

8

5.25

230

150

5.09

14

11

10.2

7

5.5

220

160

7.21

12

12

14.4

6

6

210

160

11.04

8

14

22.1

4

7

180

150

12.6

7

16

25.2

3.5

8

150

150

15.68

Stall

 

31.4

Stall

 

 

 

HERCULINK FRAME 2 PERFORMANCE

Line Pressure (motor running) at Motor inlet: 90 psig (6.2 bar)

Hoist Capacities

Air flow for all sizes

37-1/2 ton

50 ton

 

Hoist Speed

 

Hoist Speed

Load

Ft/min

Load

Ft/min

Up

Scfm

Ton

Up

Down

Ton

Up

Down

Scfm up

down

0

6.3

2.3

0

4.75

1.75

275

140

0.8

6.3

2.7

1.0

4.75

2

260

140

3.5

6.0

2.8

4.7

4.5

2.13

240

140

6.3

5.7

3.3

8.4

4.25

2.5

230

140

9.0

5.3

3.5

12.1

4

2.63

230

150

15.3

4.7

3.7

20.4

3.5

2.75

220

160

21.6

4.0

4.0

28.8

3

3

210

160

33.1

2.7

4.7

44.2

2

3.5

180

150

37.8

2.3

5.3

50.4

1.75

4

150

150

47

Stall

62.7

Stall

Test date: 6/27/98 tested by: Tadios Tsegaye Engineering: Manjit Bains Marketing: Edwige Dheilly

 

 

Return  to Index

 



Sales/Service Locator
Technical Publications
Warranty Registration
Login
What's in Stock
Specials
Options
 

Get the scoop from IR's experts! IR's Uplink news letters provide answers to frequently asked technical questions, including specs and diagrams where appropriate.
 
 
 

Ingersoll Rand Corporation